Shelly
Shelly 3EM-63T Gen3
Shelly 3EM-63T Gen3
Low stock
A compact energy meter with flat terminals that can track a three-phase system or three separate single-phase circuits. It connects easily to smart home or professional setups and delivers real-time, accurate data to help improve energy efficiency.
Key features
- 4-quadrant measurement
- Multiple connection types: three-phase or single-phase installations
- Non-contact current measurements via current transformers
- Phase sequence error detection (optional)
- No-load threshold
- Optical pulse indication of energy usage
- Real-time clock — data timestamps remain accurate even without internet
- Data logs: up to 7 days stored on the device for later retrieval
- Accuracy Class B (IEC 62053-21)
- Photovoltaic ready
Couldn't load pickup availability
Technical details
Technical details
Device identification
Name: Shelly 3EM-63W Gen3 (Wire model) / Shelly 3EM-63T Gen3 (Flat terminal model)
Model: S3EM-003CXCEU63
Device SSID: Shelly3EM63G3-XXXXXXXXXXXX
BLE Model ID: 0x1026
Short description
Shelly 3EM-63 Gen3 is a compact energy meter for monitoring a three-phase system or three independent
single-phase circuits. Works standalone on Wi-Fi or via cloud automation (MQTT, HTTP, WebSocket with TLS).
Reports real-time energy, voltage, current, and power per phase. Stores 7 days of 1-minute interval data
in non-volatile memory. Built-in RTC ensures correct timestamps even if SNTP is unavailable.
Can be accessed and managed locally or remotely through web interface and home automation platforms.
Main features
- 4-quadrant measurement
- On-MCB mounting: above¹ or below the breaker
- Supports three-phase or single-phase installations
- Non-contact measurement via current transformers
- Phase sequence error detection² (optional)
- No load threshold³
- Optical pulse indication of energy usage
- Real-time clock keeps timestamps offline⁴
- Data logs: up to 7 days stored
- Accuracy Class B (IEC 62053-21)
- Photovoltaic ready
¹ Shelly 3EM-63T Gen3 only.
² Phase sequence error detection monitors phase zero-crossings; detects A-B-C vs A-C-B sequence.
³ Loads <30 VA per channel: power shown but no energy accumulated.
⁴ Built-in RTC provides timestamps during network interruptions.
Use cases
- Power monitoring: Real-time consumption tracking
- Energy efficiency: Optimize usage patterns
- Appliance health: Detect unusual consumption spikes
- Cost management: Estimate and reduce electricity bills
- Space-efficient install: Mount above/under DIN breaker
- Remote monitoring: Publish to cloud systems, monitor anywhere
- Local monitoring: Access stored records from web interface; enable local automation
Device electrical interfaces
Inputs: 3 live inputs (LA, LB, LC), plus neutral (N)
3EM-63T Gen3: Flat terminals
3EM-63W Gen3: Color-coded wires
Connectivity
Wi-Fi
Bluetooth
Safety function
Internal temperature sensing and reporting
Supported load types
- Resistive (bulbs, heaters)
- Capacitive (capacitor banks, electronics, motor capacitors)
- Inductive (drivers, fans, refrigerators, ACs, etc.)
User interface
Inputs: One tactile dome button
• Hold 5s → enable AP
• Hold 10s → factory reset
Outputs: LED indication
• AP mode → Blue
• STA mode, not connected → Red
• STA mode, connected (cloud disabled) → Yellow
• STA mode, connected (cloud enabled) → Green
• OTA update → Flashing Red/Blue
• Energy counting → Red flashing, f
Specifications
Specifications
Physical
Size (HxWxD): 21×54×42 mm / 0.83×2.13×1.65 in (Shelly 3EM-63W Gen3, without wires); 31×54×42 mm / 1.22×2.13×1.65 in (Shelly 3EM-63T Gen3, without wires)
Wires length: 260 mm (including flat terminal)
Weight: 58 g / 2.05 oz (Shelly 3EM-63W Gen3, including wires); 52 g / 1.83 oz (Shelly 3EM-63T Gen3, including wire)
Conductor aperture: Ø8 mm / Ø0.3 in
Mounting: Above or under DIN-rail mounted circuit breakers
Shell material: Plastic
Color: White
Environmental
Ambient temperature: −20 °C to 40 °C (−5 °F to 105 °F)
Humidity: 30–70% RH
Max altitude: 2000 m (6562 ft)
Electrical
Power supply: 220–240 V~ 50/60 Hz (between LA and N)
Power consumption: < 2 W
External protection: 63 A, tripping characteristic B or C; 6 kA interrupting rating; energy limiting class 3
Sensors & Meters
Internal temperature sensor: Yes
Voltmeters (RMS per phase): 220–240 V~ 50/60 Hz
Voltmeters accuracy: Better than ±1%
Ammeters (RMS via integrated CT per phase): 0–63 A (130 A saturation)
Ammeters accuracy: ±1% (2–63 A), ±2% (1–2 A), ±5% (0–1 A)
Power & energy meters: Active and apparent power; active and apparent energy; power factor; fundamental active and fundamental reactive energy
No load threshold: 30 VA
Measurement data storage: At least 7 days at 1 min resolution
Data export: CSV for PQ recorded values; JSON export via RPC
Radio
Wi-Fi protocol: 802.11 b/g/n
Wi-Fi RF band: 2401–2483 MHz
Wi-Fi max RF power: < 20 dBm
Wi-Fi range: Up to 30 m / 100 ft indoors; 50 m / 160 ft outdoors (depends on conditions)
Bluetooth protocol: 4.2
Bluetooth RF band: 2400–2483.5 MHz
Bluetooth max RF power: < 4 dBm
Bluetooth range: Up to 10 m / 33 ft indoors; 30 m / 100 ft outdoors (depends on conditions)
MCU
CPU: ESP-Shelly-C38F
Flash: 8 MB
Firmware capabilities
Schedules: 20
Webhooks: 20 (up to 5 URLs each)
Scripting: Yes
MQTT: Yes
Share